Specifications
| Bulky Item | No |
|---|---|
| Contains Button Battery | No |
| Dangerous Goods | No |
| Pack Quantity | 1 |
Description
CyberPower OL6KERTHD guarantees power backup protection for IT equipment, servers, workstations, NAS/Storage devices, telecom devices, networking devices, security/emergency and surveillance systems. The UPS adopts double-conversion topology. Specifications: Phase: Single Phase Form Factor: Rackmount, Tower UPS Topology: Online Double Conversion Energy Saving Technology: Online ECO Mode Efficiency > 97% Active PFC Compatibility: Yes Generator Compatibility: Yes Nominal Input Voltage ( Vac ): 200 ± 2% | 208 ± 2% | 220 ± 2% | 230 ± 2% | 240 ± 2% Input Voltage Range ( Vac ): 200 - 240 Adjustable Voltage Range ( Vac ): 0-25% Load for 120 - 139 Vac | 0-50% Load for 140 - 159 Vac | 0-75% Load for 160 - 179 Vac | 0-100% Load for 180 - 280 Vac Input Frequency ( Hz ): 50 ± 10 | 60 ± 10 Input Frequency Detection: Auto-sensing Rated Input Current ( A ): 32 Input Power Factor: 0.99 Input Connector Type: Hardwire Terminal Block Output Capacity (Watts): 6000 On Battery Waveform: Pure Sine Wave On Battery Voltage(s) ( Vac ): 200 ± 2% | 208 ± 2% | 220 ± 2% | 230 ± 2% | 240 ± 2% Output Voltage Setting: Configurable On Battery Frequency ( Hz ): 50 ± 0.5% | 60 ± 0.5% Output Frequency Setting: Configurable Power Factor: 1 ECO Mode Voltage Tolerance: ± 10 % | ± 15 % Overload Protection: Internal Current Limiting, Circuit Breaker Overload Protection (Line Mode): 105-125% Load for 1 min, 125-150% Load for 10 sec Overload Protection (Battery Mode): 105-130% Load for 10 sec, 130-150% Load for 2 sec Overload Protection (Bypass Mode): Circuit Breaker Crest Factor: 3 : 1 Harmonic Distortion (Linear Load): THD 3% Harmonic Distortion (Non-linear Load): THD 5% Internal Bypass: Automatic Bypass, Manual Bypass Outlet(s) - Total: 7 Outlet Type: IEC C13 x 4 | IEC C19 x 2 | Hardwire Terminal Block x 1 Outlet(s) - Battery & Surge Protected: 7 Outlet(s) - Critical Load (CL): 4 Outlet(s) - Non-Critical Load (NCL): 3 Typical Transfer Time ( ms ): 0 Runtime at Half Load ( min ): 4.9 Runtime at Full Load ( min ): 1.4 Typical Recharge Time ( Hours ): 4 Start On Battery: Yes Smart Battery Management (SBM): Yes Built-in Battery Management Module: Yes User-replaceable: Yes - Qualified Personnel Only Hot-swappable: Yes Battery Type: Sealed Lead-acid Replacement Battery Pack: RBP0144 RBP Quantity ( pcs ): 1 Battery Quantity (Each RBP) ( pcs ): 12 Battery Voltage (Each RBP) ( V ): 144 Compatible Extended Battery Module (EBM): BPE144VL2U01 (Built-in Charger) Max. EBM Quantity ( pcs ): 10 Surge Suppression ( Joules ): 2430 EMI/RFI Filtration: Yes LCD Orientation: Rotatable LCD - Automatic, Rotatable LCD via Setting Tiltable LCD Panel: 18° LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting, Language HID Compliant USB Port(s): 1 Emergency Power Off (EPO) Port: Yes Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery Management Cable ( pcs ): USB Cable x1, Serial Cable x1 Power Management Software: PowerPanel Business (Recommended) SNMP/HTTP Remote Monitoring: Yes - RMCARD205 included Enclosure Construction: Metal Rackmount Rail: Yes Rackmount Ears: Yes Dimensions: 433 x 86.5 x 720mm Rack-mounted Dimensions: 433 x 86.5 x 685mm (Without the dimension of front panel) Weight: 42kg Certifications: CE, EAC, RCM Features: Online (Double Conversion) UPS Topology High Density Design High Output Power Factor Tiltable LCD Panel Surge and Spike Protection Generator Compatible Hot-swappable Batteries Smart Battery Management (SBM) SNMP/HTTP Remote Management Capability ECO Mode Color LCD Panel Quick Charging Technology Automatically rotatable LCD Critical/Non-critical Load Outlets Battery Management Technology Extended Battery Module (EBM) Emergency Power Off (EPO) Port PowerPanel Management Software
Delivery
Orders are dispatched from our Australian distribution partners. Delivery estimates are confirmed at checkout against live supplier availability, and you will receive tracking as soon as your order ships.
Larger orders may arrive in more than one shipment, each tracked separately. Until customer accounts are available, contact our team for the status of a shipment.
Warranty, returns and support
This product carries the manufacturer’s Australian warranty. Your rights under the Australian Consumer Law apply in addition to any warranty and cannot be excluded.
See returns and refunds, warranty claims, or contact our support team.